@@ -233,39 +233,58 @@ export function calcConcreteTempPass(TaArr, radArr, vaArr, elevArr, uvArr, cloud
}
// -------------------------------------------------------------------
// UK HOUSE INDOOR TEMPERATURE (windows closed, no active cooling)
// UK HOUSE INDOOR TEMPERATURE - TWO-NODE THERMAL MODEL
// -------------------------------------------------------------------
// Estimates the ambient indoor air temperature of a typical UK brick
// house with windows closed and no air conditioning.
// Estimates the free-running indoor air temperature of the selected
// BUILDING_TYPES preset when EMPTY: no heating, no air conditioning, no
// occupants - only standby appliances (fridge, router) as internal gain.
//
// Two heat pathways are modelled:
// Each hour builds an outdoor-driven TARGET - where the room would settle
// if this hour's conditions held forever:
//
// 1. WALL CONDUCTION
// Heat conducts through brick cavity walls and roof. UK Part L
// compliant walls have a U-value around 0.28-0.45 W/m-K; older
// solid-brick stock runs higher. A representative mid-stock value
// is used. This drives a slow, steady heat transfer proportional
// to the difference between outdoor and indoor air temperature.
// target = outdoor ref + solar lift + standby gain
//
// 2. WINDOW SOLAR GAIN
// A typical UK semi has ~15-18% glazing ratio. Solar energy
// transmits through glass, is absorbed by floors and furniture,
// and heats the indoor air. Gain is averaged across orientations
// (not all windows face south). Diffuse radiation contributes
// regardless of sun angle.
// outdoor ref blend of outside air, the ground and heated neighbours:
// Ta x (1 - groundCoupling - neighbourCoupling)
// + ground temp x groundCoupling
// + neighbour temp x neighbourCoupling
// Heat lost through the floor goes to the ground, not the
// air, and UK ground under a building sits near 6.5-14.5 C
// through the year (ukGroundTempC). This is what keeps an
// empty house above freezing in a cold snap and a little
// cooler in a heatwave - with a FIXED gap per degree, not a
// thermostat-like one.
// Neighbours (party walls/floors of terraces and flats) are
// occupied homes: never below NEIGHBOUR_MIN_C (they heat), and
// otherwise assumed the same as this building, so no flow.
// solar lift glob x glazingRatio x gValue x orientFactor x solarScale
// (tent: glazingRatio stands in for the sunlit fabric)
// standby gain fridge/router/standby loads in an empty building (C)
//
// THERMAL LAG
// Brick and concrete have high thermal mass - the house responds
// slowly to outdoor temperature swings. Each hour builds a realistic
// target temperature from outdoor air, window solar gain, retained
// warmth, and internal gains, then the room temperature lags toward
// that target. This avoids runaway accumulation while still giving
// the characteristic late-day indoor peak.
// Call calcIndoorTempPass() on the full hourly arrays after
// building rows - it returns a per-hour indoor temp array.
// The room is then modelled as TWO coupled nodes rather than one lag:
//
// No mechanical cooling. Minimal infiltration (windows closed).
// Internal heat gains (people, appliances) are not modelled.
// 1. ROOM AIR (Ti) - fast node, time constant lagHours. Its equilibrium is
// a blend of the outdoor-driven target and the thermal mass:
// airEq = (1 - massCoupling) x target + massCoupling x Tm
// massCoupling is how strongly the walls/floors hold the air compared
// with the outdoor pull through glass, fabric and leakage.
//
// 2. THERMAL MASS (Tm) - slow node, time constant massHours. Walls, floors
// and furniture exchange heat with the room air.
//
// Why two nodes: a single exponential lag lets ~70% of the outdoor daily
// swing through for a 4 h brick constant, so a brick house swung 21-34 C on
// an 18-32 C day. Monitored UK homes swing roughly a third of the outdoor
// range and instead RATCHET UP over a multi-day heatwave as the mass warms -
// the slow node reproduces both. The effective outdoor time constant of the
// mass is massHours / (1 - massCoupling) - about 1.5 days for brick.
//
// The forecast starts at midnight with no history, so the model is spun up
// by cycling the first day SPIN_UP_DAYS times (assumes the days before the
// forecast resembled the first one) instead of starting the mass cold.
//
// Indoor CAN be cooler than outdoor (a stone cottage on a hot afternoon);
// the only clamp is a 55 C physical cap.
//
// Colour thresholds:
// < 20 -C - cool, may need heating
@@ -274,94 +293,162 @@ export function calcConcreteTempPass(TaArr, radArr, vaArr, elevArr, uvArr, cloud
// > 32 -C - hot; risk for elderly and vulnerable occupants
// -------------------------------------------------------------------
// Two-pass function: call with the full arrays of hourly Ta and globalRad.
// Returns an array of indoor temperatures, one per hour.
// buildingType must be a key of BUILDING_TYPES; defaults to 'brick'.
export function calcIndoorTempPass(TaArr, globArr, elevArr, buildingType = 'brick') {
const preset = BUILDING_TYPES[buildingType] || BUILDING_TYPES.brick;
const { lagHours, glazingRatio, gValue, orientFactor, solarScale, baseTemp, internalGain, retainedScale } = preset;
// Days of the first forecast day replayed to warm up the thermal mass.
const SPIN_UP_DAYS = 5;
// Managed mode switches to the heatwave routine on any day forecast to reach
// this outdoor temperature, or whenever the room itself passes HOT_INDOOR_C.
const HOT_DAY_OUTDOOR_C = 24;
const HOT_INDOOR_C = 23;
// Windows are only opened to cool while the room is above this, so night
// ventilation never chills the house below a comfortable sleeping temp.
const VENT_FLOOR_C = 20;
// UK ground temperature at ~1 m under a building for a day of year.
// Annual mean ~10.5 C, swing +/-4 C, coldest early March, warmest early
// September (the ground lags the air by ~6 weeks). UK/northern-hemisphere
// climate assumed, matching the rest of the building model.
const GROUND_MEAN_C = 10.5;
const GROUND_SWING_C = 4;
const GROUND_COLDEST_DOY = 65;
// Occupied neighbours keep their homes at least this warm in cold weather.
const NEIGHBOUR_MIN_C = 18;
function ukGroundTempC(dayOfYear) {
return GROUND_MEAN_C - GROUND_SWING_C * Math.cos(2 * Math.PI * (dayOfYear - GROUND_COLDEST_DOY) / 365);
}
// One hour of the indoor model. Mutates and returns state { Ti, Tm }.
// managed - false: windows closed, curtains open all the time (passive)
// true : occupant follows the routine for the conditions -
// HEAT (hotDay): curtains closed while the sun is up,
// windows opened whenever outdoor air is cooler
// COOL: windows shut, curtains open by day to let the sun
// in, closed after dark to cut window heat loss
function indoorStep(state, Ta, glob, preset, managed, hotDay, groundTemp) {
const { lagHours, massHours, massCoupling, glazingRatio, gValue, orientFactor,
curtainBlock, curtainInsul, ventAlpha, solarScale, groundCoupling,
neighbourCoupling, internalGain } = preset;
const heatMode = managed && (hotDay || state.Ti >= HOT_INDOOR_C);
const coolMode = managed && !heatMode;
// Solar gain - only blocked when managing for heat and the sun is up.
const block = heatMode ? curtainBlock : 0;
const solarLift = glob * glazingRatio * gValue * orientFactor * solarScale * (1 - block);
// Outdoor pull is split between outside air, the ground under the floor
// and any heated neighbours through party walls/floors.
const neighbourTemp = Math.max(state.Ti, NEIGHBOUR_MIN_C);
const outdoorRef = (1 - groundCoupling - neighbourCoupling) * Ta
+ groundCoupling * groundTemp
+ neighbourCoupling * neighbourTemp;
let target = outdoorRef + solarLift + internalGain;
// Cool routine after dark: closed curtains cut window heat loss, so the
// room is pulled less hard toward outdoor - curtainInsul is the share of
// the outdoor heat loss they save.
if (coolMode && glob <= 0 && target < state.Ti) {
target += (state.Ti - target) * curtainInsul;
}
// Room air relaxes toward a blend of the outdoor pull and the mass.
const airEq = (1 - massCoupling) * target + massCoupling * state.Tm;
const aAir = 1 - Math.exp(-1 / lagHours);
const aMass = 1 - Math.exp(-1 / massHours);
state.Ti += aAir * (airEq - state.Ti);
// Heat routine: open windows only when outside is cooler and the room is
// still above the comfort floor; never ventilate below that floor.
if (heatMode && Ta < state.Ti && state.Ti > VENT_FLOOR_C) {
const vented = state.Ti + ventAlpha * (Ta - state.Ti);
state.Ti = Math.max(vented, VENT_FLOOR_C, Ta);
}
// Mass exchanges with the (possibly ventilated) room air - this is how
// night purging cools the fabric for the next day.
state.Tm += aMass * (state.Ti - state.Tm);
return state;
}
// Shared driver for the passive and managed passes.
// Hourly arrays are assumed to start at local midnight (forecast_days fetch),
// so hour i belongs to forecast day floor(i / 24).
// startIso is the first hour's ISO time (for the seasonal ground temp); if
// missing the annual mean ground temperature is used.
function runIndoorModel(TaArr, globArr, buildingType, managed, startIso) {
const preset = BUILDING_TYPES[buildingType] || BUILDING_TYPES.brick;
const n = TaArr.length;
const result = new Array(n);
const alpha = 1 - Math.exp(-1 / lagHours); // per-hour blending weight
// Seed to a plausible occupied indoor baseline rather than outdoor air.
let Ti = Math.max(TaArr[0] ?? 15, baseTemp ?? 16);
// Ground changes only ~0.5 C over a 14-day forecast - one value is enough.
const start = startIso ? new Date(startIso.slice(0, 10) + 'T00:00:00Z') : null;
const doy = start && !isNaN(start)
? Math.floor((start - Date.UTC(start.getUTCFullYear(), 0, 1)) / 86400000) + 1
: null;
const groundTemp = doy != null ? ukGroundTempC(doy) : GROUND_MEAN_C;
// Daily outdoor maxima decide the managed routine for each forecast day.
const dayMax = [];
for (let i = 0; i < n; i++) {
const d = Math.floor(i / 24);
const Ta = TaArr[i];
if (Ta != null) dayMax[d] = Math.max(dayMax[d] ?? -Infinity, Ta);
}
const isHotDay = i => (dayMax[Math.floor(i / 24)] ?? -Infinity) >= HOT_DAY_OUTDOOR_C;
// Seed both nodes at the first hour's air temp, then spin up on day one.
const seed = TaArr[0] ?? groundTemp;
const state = { Ti: seed, Tm: seed };
const spinHours = Math.min(24, n);
for (let rep = 0; rep < SPIN_UP_DAYS; rep++) {
for (let i = 0; i < spinHours; i++) {
indoorStep(state, TaArr[i] ?? state.Ti, globArr[i] ?? 0, preset, managed, isHotDay(i), groundTemp);
}
}
for (let i = 0; i < n; i++) {
const Ta = TaArr[i] ?? Ti;
const glob = globArr[i] ?? 0;
// Solar gain through windows (W/m- effective)
const solarGain = glob * glazingRatio * gValue * orientFactor;
const retainedWarmth = Math.max(0, (baseTemp ?? 16) - Ta) * (retainedScale ?? 0.35);
const target = Ta + solarGain * (solarScale ?? 0.1) + retainedWarmth + (internalGain ?? 0.7);
// Apply thermal lag: blend toward the hour's target instead of adding
// solar gain repeatedly onto the previous indoor temperature.
Ti = Ti + alpha * (target - Ti);
// Can't be colder than outdoor (house doesn't actively cool)
result[i] = Math.max(Math.min(Ti, 55), Math.min(Ta, Ti));
const Ta = TaArr[i] ?? state.Ti;
indoorStep(state, Ta, globArr[i] ?? 0, preset, managed, isHotDay(i), groundTemp);
result[i] = Math.min(state.Ti, 55);
}
return result;
}
// -------------------------------------------------------------------
// UK HOUSE INDOOR TEMPERATURE - MANAGED (curtains closed, windows open)
// -------------------------------------------------------------------
// Models the same UK brick house as calcIndoorTempPass but with two
// behavioural interventions that reflect standard heatwave advice:
//
// 1. CURTAINS CLOSED
// Thick curtains block ~80% of window solar gain before it enters
// the room. The small remaining fraction is diffuse light through
// the curtain fabric. Wall conduction is unchanged.
//
// 2. WINDOWS OPEN (smart ventilation)
// When outdoor air is cooler than the indoor air, windows are open
// and a ventilation heat exchange pulls the indoor temp toward
// outdoor. When outdoor is hotter than indoor, windows are kept
// shut - so this strategy never makes things worse, only better.
// Ventilation rate ~2 air changes/hour for a well-opened house.
//
// Same thermal lag model as calcIndoorTempPass (4 h brick time constant).
// -------------------------------------------------------------------
// PASSIVE: empty building, windows closed, curtains open, no heating or cooling.
// Returns an array of indoor temperatures, one per hour.
// buildingType must be a key of BUILDING_TYPES; defaults to 'brick'.
export function calcManagedIndoorTempPass(TaArr, globArr, elevArr, buildingType = 'brick') {
const preset = BUILDING_TYPES[buildingType] || BUILDING_TYPES.brick;
const { lagHours, glazingRatio, gValue, orientFactor, curtainBlock, ventAlpha, solarScale, baseTemp, internalGain, retainedScale } = preset;
// elevArr is accepted for signature compatibility but not needed - the
// orientFactor average already covers sun angle on the glazing.
// startIso (optional) - first hour's ISO time, sets the seasonal ground temp.
export function calcIndoorTempPass(TaArr, globArr, elevArr, buildingType = 'brick', startIso) {
return runIndoorModel(TaArr, globArr, buildingType, false, startIso);
}
const n = TaArr.length;
const result = new Array(n);
const alpha = 1 - Math.exp(-1 / lagHours);
let Ti = Math.max(TaArr[0] ?? 15, baseTemp ?? 16);
for (let i = 0; i < n; i++) {
const Ta = TaArr[i] ?? Ti;
const glob = globArr[i] ?? 0;
// Solar gain - curtains block curtainBlock fraction
const solarGain = glob * glazingRatio * gValue * orientFactor * (1 - curtainBlock);
const retainedWarmth = Math.max(0, (baseTemp ?? 16) - Ta) * (retainedScale ?? 0.35);
const target = Ta + solarGain * (solarScale ?? 0.1) + retainedWarmth + (internalGain ?? 0.7);
// Apply thermal lag toward the managed target.
Ti = Ti + alpha * (target - Ti);
// Smart ventilation: only open windows when outside is cooler
if (Ta < Ti) {
Ti = Ti + ventAlpha * (Ta - Ti);
}
result[i] = Math.max(Math.min(Ti, 55), Math.min(Ta, Ti));
}
return result;
// -------------------------------------------------------------------
// UK HOUSE INDOOR TEMPERATURE - MANAGED
// -------------------------------------------------------------------
// The same empty building, but with its curtains and windows set sensibly
// for the conditions (by a visiting owner or smart blinds - see indoorStep):
//
// HEAT routine (day forecast >= HOT_DAY_OUTDOOR_C, or room >= HOT_INDOOR_C)
// Standard UK heatwave advice. Curtains/blinds closed while the sun is up
// (curtainBlock - internal curtains only stop ~40-55% because the heat
// is already through the glass; external shutters would be ~80%+).
// Windows opened whenever outdoor air is cooler than inside, down to a
// VENT_FLOOR_C comfort floor - so it never makes things worse.
//
// COOL routine (all other days)
// Windows shut. Curtains open in daylight to bank free solar gain,
// closed after dark to cut window heat loss (curtainInsul). Managed is
// therefore slightly WARMER than passive on cool days, not colder.
// -------------------------------------------------------------------
export function calcManagedIndoorTempPass(TaArr, globArr, elevArr, buildingType = 'brick', startIso) {
return runIndoorModel(TaArr, globArr, buildingType, true, startIso);
}
// -------------------------------------------------------------------